Case Study · Textile Finishing

Stenter Frame Oven Burner for a Textile Finishing Line

An 8-zone stenter oven needed even heat to set fabric without curling edges. Baltur modulating burners with an integrated Dungs combo valve gave stable zone temperatures and saved gas.

Textile finishing — stenter (tenter) frame oven 8-zone stenter, continuous fabric
Gas burner bank on a textile stenter frame oven

The challenge

01

Uneven zone heat curled fabric edges and spoiled finish consistency.

02

The old two-stage burners could not track line-speed changes smoothly.

03

Gas-pressure dips tripped shutdowns and broke the finishing run.

04

Energy cost per metre was above target.

What we supplied & did

01

Fitted Baltur TBG120 modulating burners across the 8 stenter zones.

02

Used Dungs integrated combo valves to absorb upstream pressure dips.

03

Added pressure monitoring and Honeywell flame detection with interlock cutoff.

04

Tuned high/low-load curves on site to even each zone's hot-air band.

Measured results

What changed on the line

Zone heat: Even, no curl Load range: 20-100% smooth Gas saving: ≈ 10% NOx: Compliant

All eight zones hold even heat; edge curl and finish rejects dropped.

Modulating burners follow line-speed changes without hunting.

Combo valves absorbed pressure dips, ending unexplained shutdowns.

Gas use fell about 10% over the finishing campaign.